Bioburden testing Key criteria related to bioburden

Irradiation Sterilization of Medical Devices (6) Bioburden Detection Bioburden Detection The effectiveness of radiation sterilization depends on the amount and type of bioburden on the product. Therefore, it is necessary to measure the bioburden when determining the sterilization dose, and measure it regularly every day Bioburden, and measure the bioburden during dose audit. Once the development of bioburden or type of enterprise changes, it may cause the failure of sterilization dose audit and affect the effectiveness of the original sterilization dose. Therefore, in daily operation management In the process, various social factors that may affect bioburden need to be controlled, such as materials, production and living environment, production process, product market structure, composition, etc. When these factors change, their impact on bioburden needs to be carefully evaluated. Bioburden detection The main standards related to bioburden are as follows: GB/T 19973.1-2015 ISO 11737-1: Microbiological methods for sterilization of medical devices 2006 Part 1: Determination of total microbial load on products GB/T 19973.2-2018 idt ISO 11737 -2:2009 Sterilization of medical service devices - Microbiological research methods - Part 1: Definition, validation and maintenance of sterilization processes

22-08-25 10:19

Bioburden testing Key criteria related to bioburden

Irradiation Sterilization of Medical Devices (6) Bioburden Detection

 

Biological The effectiveness of load detection radiation sterilization depends on the amount and type of bioburden on the product. Therefore, the bioburden must be measured when determining the sterilization dose, periodically on a daily basis, and at dose audits. Once the development of bioburden or type of enterprise changes, it may lead to the failure of the sterilization dose audit and affect the effectiveness of the original sterilization dose that can be set. Therefore, in daily operation and management, it is necessary to control various social factors that may affect bioburden, such as materials, production and living environment, production process, product market structure, composition, etc. As these factors change, their impact on bioburden needs to be carefully assessed.

 

The main criteria for bioburden testing related to bioburden are as follows:

 

GB/T 19973.1-2015 ISO 11737-1: Microbiological methods for sterilization of medical devices 2006 No. 1 Part: Determination of Total Microorganisms on Products

 

GB/T 19973.2-2018 idt ISO 11737-2:2009 Sterilization of medical service devices - Methods of microbiological studies - Part 1: Sterility tests for definition, validation and maintenance of sterilization processes

 

< p> Bioburden detection collection technology is another important factor affecting the results of bioburden determination. The first decision to use bioburden collection technology is the format of the product. For liquid or soluble medical devices or their components, membrane filtration can be used directly, but it may be necessary to consider whether there are fibers or particles remaining in the liquid or after dissolution. Effect of substances on filtration. However, for poorly soluble medical devices, regardless of the influence of SIP, bioburden measurement is only an estimate and accurate results are neither possible nor necessary.

 

 

1. The number of original microorganisms attached to the medical device is unknown. Gaps in assessments using vaccination methods can be very large. Therefore, it is almost impossible to evaluate whether a certain collection technology is suitable for a certain medical device product, and can only be selected based on factors such as product characteristics, experience, and ease of operation. The appendix of 19973.1 gives information collection techniques commonly used by some enterprises, such as bag peristalsis, ultrasonic elution, shaking, vortex mixing, rinsing, stirring and cutting (crushing), wiping, etc., and gives some methods that can be used Requirements and safety precautions are required.

 

2. Bioburden detection, when collecting bioburden, if the used Collection techniques lead to the death of microorganisms, or if the collection takes too long and results in growth of microorganisms, the obtained bioburden may deviate from the actual value. Since enterprises cannot predict the original microorganisms attached to medical devices, it is not reliable to use the inoculation method to evaluate the recovery rate, and it is also difficult to evaluate the possibility of microbial death or growth caused by the development of information collection data technology. question. Of course, for some products, it may be possible to assess by inoculation. Therefore, in most cases, the collection method and eluent can be selected according to some instructions in 19973 and the Chinese Pharmacopoeia, combined with product characteristics, and the collection time should be minimized to avoid the growth of microorganisms. However, after choosing a collection technique and determining parameters, conditions can be compared by inoculation or by deliberately increasing bioburden. For example, evaluation of acquisition parameters such as shaking frequency, shaking time, sequence, etc.

 

The role of the correction factor is mainly in the selection of the method for determining the sterilization dose. The effectiveness of the sterilizing dose was not significantly affected. Of course, the correct and reasonable selection of research methods for the determination of sterilization dose is also an important factor affecting the effectiveness of sterilization dose. If the establishment method is not chosen correctly, it is difficult to say whether the effectiveness of the sterilization dose can be guaranteed.

More news

Notice of the General Department of the State Food and Drug Administration on Printing and Distributing the Work Procedures for the Inspection of the Quality Management System for the Registration of Class III Medical Devices in China

Water quality testing

Water quality testing and testing indicators

Current status and development of medical device testing

Quality Control Measures of Medium in Microbiological Testing

Clean room testing methods and procedures

Renkang Electronics
%{tishi_zhanwei}%

9/F, Building 5, Area A, Hongchuang Science and Technology Center, Longhua District, Shenzhen

Business License

© Copyright Shenzhen King Medical Testing Technology Co., Ltd. All rights reserved.